Vibromera OU

Estonia,Ida-Viru maakond, Narva linn, Kiriku tn 13, 20308      
E-mail: info@vibromera.eu    info@vibromera.com

4-plane balancing calculator
How to use
Run#0 Original vibration - Start-up without test weight.
1. Run the machine at its operating speed (be sure that operating speed is far from resonance frequency of construction)
2. Measure the 1x RPM vibration level and phase angle.
If you have single channel vibrometer, you need measure vibration 4 times for Plane1,2,3,4.
3. Input measured data in the corresponding fields of balancing calculator.
(Panel Run#0 Original vibration, Vo1 and F1 for Plane1 and Vo2 and F2 for Plane2 etc.)

Run#1-Run#3 Test weight in Plane 1-3
4. Stop the machine and mount a test weight of suitable size in Plane 1(2,3).
5. Run the machine and measure the new 1x RPM vibration level and phase angle.
6. Stop the machine and remove the test weight
7. Input measured data in the corresponding fields of balancing calculator.
(Panel Run#1(2,3) Test weight in Plane 1(2,3), Vo1 and F1 for Plane1 and Vo2 and F2 for Plane2 etc.)

Run#4 - Test weight in Plane 4
8. Mount a trial weight of suitable size in Plane 42.
9. Run the machine again and measure the 1x RPM vibration level and phase angle once more.
10. Stop the machine and remove the test weight
11. Input measured data in the corresponding fields of balancing calculator.
(Panel Run#4 Test weight in Plane 4,Vo1 and F1 for Plane1 and Vo2 and F2 for Plane2 etc.)
12. Press button F9 Calculate, read results and mount correcting weights of the calculated masses in the angles F1.. F4 (at the same radius as the test (trial) weights) from the test weight place (angle) by the rotation direction.

RunC-Trim balancing
13. Run the machine again and measure the amount of vibration, to see how successful the balancing job has been.
4-plane dynamic balancing calculator. Main window-Main window-input vibration data and calculate balancing weights and angles
4-plane dynamic balancing calculator. Where to place balancing weights